Page 85
** Command Control Options **
P881E Command code for Area “A” control Page 63
P882E Command code for Area "B" control Page 63
P883E Command code for Area "C" control Page 63
P884E Command code for Area "D" control Page 63
P885E Command code for output control Page 63
P886E Command code to turn “MICROPHONE” On Page 63
**Keypad Panic Alarm Contact ID Reporting Code**
P887E Keypad Panic Alarm (& button 1 & 3) Contact ID Code (Default=120) Page 59
**Keypad Fire Alarm Contact ID Reporting Code**
P888E Keypad Fire Alarm (button 4 & 6) Contact ID Code (Default=110) Page 59
**Keypad Medical Alarm Contact ID Reporting Code**
P889E Keypad Medical Alarm (button 7 & 9) Contact ID Code (Default=100) Page 59
** Dialler Options **
P890E Dialler options (Default = 2,7) Page 54
1 = Enable dialler 5 = Reverse Style Pulse
2 = Fax defeat 6 = Report 24hr alarms in Voice/Domestic
3 = Disable line monitoring 7 = Auto-Detect Modem Format
4 =Pulse Dial (Off = DTMF) 8 = Force V21
** Reporting Scenarios **
P892E Reporting Scenario #1 options (Default = 1,7) Page 54
P893E Reporting Scenario #2 options (Default = 0)
P894E Reporting Scenario #3 options (Default = 0)
P895E Reporting Scenario #4 options (Default = 0)
** Maximum Dialling Attempts per Scenario **
P896E Max Dial Attempts for Scenario Number 1-Value 1-99 (Default=20) Page 55
P897E Max Dial Attempts for Scenario Number 2-Value 1-99 (Default=20)
P898E Max Dial Attempts for Scenario Number 3-Value 1-99 (Default=20)
P899E Max Dial Attempts for Scenario Number 4-Value 1-99 (Default=20)
** Auto Answer Ring Count **
P900E Auto-answer ring count - default = 25 Page 61
Output Reset Times
P901E Output #1 reset time - Default 600 sec Reset time values Page 48
P902E Output #2 reset time - Default 600 sec 0 = latching
P903E Output #3 reset time - Default 600 sec 1-999 = 1 to 999 seconds
P904E Output #4 reset time - Default 600 sec
P905E Output #5 reset time - Default 0 sec
P906E Output #6 reset time - Default 0 sec
P907E Output #7 reset time - Default 0 sec
P908E Output #8 reset time - Default 0 sec
** Mains Failure Reporting Delay **
P909E Mains Fail Reporting Delay to Dialler (0-999 sec) - Default = 600 Page 48
** Zone Alarm Reporting Delay **
P910E Zone Reporting Delay to Dialler (0-999 sec) - Default = 0 Page 48
Output On Delay Times
P911E Output #1 delay on timer - Default 0 Delay time values Page 48
P912E Output #2 delay on timer - Default 0 0 = no delay
P913E Output #3 delay on timer - Default 0 1 - 999 = 1 to 999 seconds
P914E Output #4 delay on timer - Default 0
P915E Output #4 delay on timer - Default 0
P916E Output #5 delay on timer - Default 0
P917E Output #6 delay on timer - Default 0
P918E Output #7 delay on timer - Default 0
Supervised Radio Timer # 1
P919E Supervised Radio Timer # 1 (0-255 minutes) - Default = 240 Minutes Page 48