Page 82
Area “B” Time & Delay Options
P772E AREA "B" TIME AND DELAY OPTIONS -Default = 0 Page 36
1 = Arm area When Time Zone Ends
2 = Disarm area When Time Zone Starts
3 = Disable Stay Mode Exit Delay
4 = Disable Arm Mode Exit Delay
5 = Disable Stay Mode Entry Delay
6 = Disable Arm Mode Entry Delay
7 = Use special Stay Mode entry timer
8 = Report Stay Mode alarms & Bypasses via dialler
** Dialler Reporting Options for Area “B” **
P775E Area B reporting options -Default = 1 Page 37
1 = Send arm/disarm 5 = Send arm when exit delay expires (LED On)
2 = Send Stay Mode arm/disarm 6 = Send all zone restores at disarm only
3 = Send disarm only after activation's 7 = Spare
4 = Send Stay Mode disarm only after alarm 8 = Spare
** Area “B” Contact ID Account Code **
P776E Account number for Area "B" - default 0000 Page 38
**Area “B” Arm/Disarm Reporting Scenario **
P777E Area B Arm/Disarm reports mapped to scenario 1-4 default 1 Page 38
**Area “B” Latchkey Disarm Reporting Scenario **
P778E Area B Latchkey Disarm Reporting scenario 1-4 default 1 Page 38
Programming Keypad Options
P780E Keypads assigned to Area "A" - Default 1-8 Page 46
P781E Keypads assigned to Area "B" - Default none Page 46
P782E Keypads assigned to Area "C" - Default none Page 46
P783E Keypads assigned to Area "D" - Default none Page 46
P784E Keypads with permission to Arm - Default 1-8 Page 46
P785E Keypads with permission to arm Stay Mode - Default 1-8 Page 46
P786E Keypads with permission to use control function - Default 1-8 Page 46
P787E Keypads with permission to bypass zones - Default 1-8 Page 46
P788E Keypads (LED) with Panic Button enabled - Default none Page 46
P789E Keypads (LED) with Delayed Panic Button enabled - Default 1-8 Page 46
P790E Keypads with dual button Panic Alarm enabled - Default 1-8 Page 46
P791E Keypads with dual button Fire Alarm enabled - Default 1-8 Page 46
P792E Keypads with dual button Medical Alarm enabled - Default 1-8 Page 46
P793E Keypads with buzzer mapped for alarm tone for armed zone alarms - Default 1-8 (see P742E) Page 46
P794E Keypads with buzzer mapped for alarm tone for stay mode zone alarms - Default 1-8 Page 46
P795E Keypads with buzzer mapped for alarm tone for 24 hour zone alarms - Default 1-8 Page 46
P796E Keypads with buzzer mapped for alarm tone for chime mode zones - Default 1-8 Page 46
P797E Keypads with buzzer mapped to indicate Arm Mode exit delay beeps - Default 1-8 Page 46
P798E Keypads with buzzer mapped to indicate Stay Mode exit delay beeps - Default 1-8 Page 47
P799E Keypads with buzzer mapped to indicate entry delay beeps - Default 1-8 Page 47
P800E Keypads with buzzer mapped for supervised radio timeout, or Sensorwatch alarm - Default none Page 47
P801E Keypads with buzzer mapped to keypad tamper - Default 1-8 Page 47
P802E Keypads with buzzer mapped to zone tamper - Default 1-8 Page 47
P803E Keypads with buzzer mapped to cabinet tamper - Default 1-8 Page 47
P804E Keypads with buzzer mapped to indicate RF signal blocked - Default none Page 47
P805E Keypads with buzzer mapped to Radio Pendant “Panic” Alarm - Default 1-8 Page 47
P806E Keypads with buzzer mapped to “Panic” Alarm - Default 1-8 Page 47
P807E Keypads with buzzer mapped to “Fire” Alarm - Default 1-8 Page 47
P808E Keypads with buzzer mapped to “Medical” Alarm - Default 1-8 Page 47
P809E Keypads with buzzer mapped to line failure - Default none Page 47
P810E Keypads with facility to turn off LED's after exit delay - Default none Page 47
P811E Keypads that will turn off all LED's and backlighting during power failure- Default none Page 47
P812E Keypad “A” Button Arm Functions -Default = 1 P812 & P813 SPECIAL FUNCTION OPTIONS Page 47
P813E Keypad “B” Button Arm Functions -Default = 2 1 = Arms Area A 5 = “Latchkey” Arming
2 = Arms Area B 6 = Spare
3 = Arms Area C 7 = Spare
4 = Arms Area D 8 = Spare
Komentáře k této Příručce